Category | Name | Parameter |
Cooling mode | Forced air cooling | |
Altitude | 2,000 m a.s.l., derating is require when the altitude is above 2,000 m a.s.l. | |
Atmospheric pressure | 79 kPa ~ 106 kPa | |
AC input | Input system | Three phases + PE |
Voltage range | 260 Vac ~ 530 Vac | |
The maximum static voltage borne under no operation | 600 Vac | |
Rated voltage | 380 Vac | |
Maximum current | 80A | |
Grid frequency | 45 Hz~ 65 Hz | |
Rated frequency | 50Hz/60Hz | |
Standby power consumption | <9W | |
Three-phase equilibrium | The difference between the maximum and minimum voltage of neutral conductor for three-phase input ≤ 10V | |
DC output | Voltage range | 150 Vdc ~ 1000Vdc |
Current range | 0 ~ 133A (current limiting point is settable) | |
Rated current | 40A (required for setting of current limiting point) | |
Steady voltage precision | <±0.5% | |
Steady current precision | ≤±1% (rated range of 20% ~ 100% for output load) | |
Load regulation rate | ≤±0.5% | |
Grid regulation rate | ≤±0.1% (testing range is 320V ~ 530V) | |
Startup overshoot | ≤±3% | |
Peak-to-peak value noise | ≤1% (200~1000V, 0~20MHz) | |
Power factor and THD | Power factor | ≥0.90 Full-load output power of @25%~50% |
≥0.98 Full-load output power of @50%~100% | ||
≥0.99 Full-load output power, input nominal voltage and frequency of @100% | ||
THD | ≤5% Full-load output power of @50%~100% | |
Efficiency | Under Rated input voltage | ≥95.0%@1000V-20A, |
EMC | Emission | ClassA According to IEC 61000-6-3 |
Immunity | According to IEC 61000-6-1 | |
Certification | CE | IEC61851-1 |
Other | Instant impulse current upon startup | <45A |
Current sharing | In case of load of 10%~100%, the module current sharing error ≤ rated output current of ±5%. | |
Noise | ≤65dB(1m away,ambient temperature is 25ºC, under rated input voltage and output is1000V-20A | |
Startup duration (select the startup mode through the monitoring module) | Normal startup mode: the time delay from AC power-on to module output is ≤ 8s. | |
Output delayed startup: The startup duration can be set through the monitoring module, with default output startup duration of 3~8s. | ||
Earthing resistance | Earthing resistance ≤ 0.1Ω, bearable current ≥ 25A | |
Lighting protection | 5kA | |
Insulation resistance | The insulation resistance of DC part and AC part to housing and the AC part to the DC part shall be ≥ 10MΩ. | |
Insulation strength | Within the 1 min of the AC input terminal to the CAN side 4242V DC voltage, there is no breakdown and flashover and the steady leakage current is less than 1mA; Within the 1 min of the AC input terminal to the enclosure 2121V DC voltage, there is no breakdown and flashover and the steady leakage current is less than 1mA; Within the 1 min of the AC input terminal to the DC output terminal 2121V DC voltage, there is no breakdown and flashover and the steady leakage current is less than 1mA; Within the 1 min of the DC output terminal to the enclosure 2121V DC voltage, there is no breakdown and flashover and the steady leakage current is less than 1mA; Within the 1 min of the DC output terminal to the CAN side 4242V DC voltage, there is no breakdown and flashover and the steady leakage current is less than 1mA; Within the 1 min of the CAN to the enclosure 707V DC voltage, there is no breakdown and flashover and the steady leakage current is less than 1mA. |
AC-DC battery charger module: