High voltage input to Dual output 120kw PV power inverter for wind-solar system
- PV Off-grid Solar Power System
PV Off-grid solar power generation system including solar panel array, solar charge controller, storage battery, Off-grid inverter, etc. In the sunshine, the solar panel convert the solar energy to DC power and charge the battery group by the charge controller. Then the off grid inverter convert the DC power into AC power for power supply the AC load.
Technical Features:
* Using the sixth generation efficient IPM intelligent module from Japanese Mitsubishi, high efficiency and stable performance. It with powerful protection function, the protection for short circuit, over load, over temperature is more safe and reliable. It's service life can up to 15 years or more.
*Two kinds of start mode: Reduction Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. This function is very convenient for users and also reduce frequency converter's usage, which reduced the cost of equipment investment, easy to connect wires and control.
* Pure sine wave output with good transient response, little harmonic distortion, higher conversion efficiency and stable output voltage features.
*Adopted low frequency isolated transformer, high conversion efficiency and stable performance
* Output AC Power is suitable for all types of home appliances, electric tools, electric motors etc.
* Converter has the function of filtering the grid disturbance and interference at the same time, which is a good performance of stabilized voltage and frequency power, to provide a more stable and pure power supply environment for the backend devices
* Safety and reliable, the input single-phase electric and output three phase electric is complete electrical isolated.
* Pure sine wave output, has higher efficiency and higher capability of driving load.
*Output perfect protection function, with output over-voltage, overload, short circuit, over temperature, self-diagnosis protection and other protection
* Powerful data display function. LCD can display the DC input voltage, output frequency, phase voltage, phase current, AC bypass input voltage, output power KWH, time and date, temperature, fault code display.
* The input voltage, output voltage, frequency and phase can be custom made.
We can make products according to your requirements.
Technical Data
Model |
BZP-120KW |
Isolation mode |
Low Frequency Transformer |
DC Input |
Rated voltage (V DC) |
480V |
Rated current(A) |
250A |
AC Output |
Rated output power |
120KW |
Output waveform |
Pure Sine Wave |
Rated Voltage |
380VAC±3% |
Phases |
3 phase 4 wire |
Rated current(A) |
181A(phase current) |
Frequency |
50Hz or 60Hz |
Rated output voltage range (V) |
380/400/415/440VAC optional |
Power Factor(PF) |
0.9 |
Overload Ability |
150%, 5 seconds |
Efficiency |
>93% |
Waveform distortion rate (THD) |
<3% linear="" load="" span=""> |
Dynamic Response (0 to 100% load) |
5%,≤50ms |
Display |
LCD |
Running mode |
Working continuously |
Electrical insulation properties |
2000Vac, 1 Minute |
Protection Function |
Protection |
Input reverse polarity, under voltage, overvoltage, output over-current, short circuit, overheating etc. |
Cooling method |
Fan-cooled |
Short-circuit protection |
No automatic recovery, need to restart the machine |
Working environment |
Noise ( 1 meter) |
≤50dB |
Degree of protection |
IP20(indoor) |
Working Altitude(m) |
≤2000 |
Working temperature |
-25~+55ºC |
relative humidity |
0~90%,non-condensing |
Mechanical dimension |
Depth* Width * Height |
900x1100x1600mm |
Weight (Kg) |
700Kg |
Above parameter only for reference ,could be custom made to user specifications.
also you can optional "dry contact control "start the generator.
1, the first normal open dry contact control generator start, when the inverter shuts off from low DC voltage,
the dry contact into normal closed status to start your generator.
2, the second normal closed dry contact, when the battery voltage recover to normal,
the inverter start to work and the normal closed dry contact disconnected, can be used to stop the generator.
In a word,we can do according to your requirements.
100-400V or 300-600V or 400-800V wide input for without battery and controller system
FAQ:
Q 1. What's the payment term?
A. We accept TT,Western Union,Paypal,MoneyGram.
Q 2.How's the delivery time ?
A. Is due to order quantity, usually it will take about 3-7days for sample production,
Q 3.Tell me the standard of package?
A. For the small capacity, it use carton, but for big capacity, we should use honeycomb carton and pallet or wooden case for protection.
Q 4.Would you accept to use our logo ?
A.It's no problem to do OEM.
Q 5.We want to know month capacity.
A. It depends on which model.For example for relay type small capacity , month capacity can reach near 2000pcs and big capacity near 500pcs.
Q 6.Where is your market?
A. Our products are popular in Australia,South America,Philippines,Italy, America, Pakistan and so on.Some of them are our regular customers and some of them are developing. We hope you can join us and make mutural benifit from our cooperation.
Q 7. What kind of certificate you have ?
A. Our company already achieve ISO9001, and for products, we have CE, SAA, G83 G59 etc .
Q8. What is the warranty period ?
A. Normally 1 year ,if order quantity enough can be extended to 3 years.
Q 8.How about the lifetime?
A:The life time for inverterl is 15-20years.
OEM Services
1.Logo
Please offer us your own high resolution logo in JPG format,there should be two colors at most in the logo and there should be no gradient effect in the logo.
2.Label
Please offer us your own model numbers.
3. Manual
Please offer us the finished manual file that can be printed directly.
Lead Time
1.Sample orders will be delivered from our factory within 3-7 working days.
2.General orders will be delivered from our factory within 15-30working days.
3.Big orders will be delivered from our factory within 45 working days at most
Shipment
1.By EMS,DHL,FedEx,TNT,UPS or other express.
2.By our forwarding agent(by air or by sea).
3.By your own forwarding agent.
4.By domestic forwarding agents to any city in China.