High Voltage and Big Current DC Contactor 9-36VDC -100A/250A/300A
- Used for industry machinery power/motor control, circuit insulation,circuit protection and safety devices etc.,
- Used for vehicle battery distribution and backup;
3,Used for inverter power control;
4,Used for electric vehicle charging hub;
5,Used for solar power plant;
6,Used for the other DC high-voltage devices.
II, Product Characteristics |
1,Controlled high current and high voltage
Sealed with the epoxy resins, filled with inactive gases inside of contactor room,combining the magnetic quenchingfor making the products bear the high current and voltage.
2,Structure is compact, the operation noise is low
Adopt the AC arc gapless structure to make the outside shape getting smaller.
Adopt the method of sealing the contactor inside of the inactive gas cabinet for ensuring the safety breaking even if the contactor gap is small.
The operation noise is low even switching the high current.
3,Good safety performance
Sealing the contactor inside of the sealed cabinet, the AC arc cannot release for ensuring the products have good safety performance.
4,Good Reliability of Contactor
Sealing the contactor unit inside of the inactive gas, the connecting resistance keeps steady whatever the environment is. And realize the dirt and water proof at the same time.
5,No Special Requirement on Installation Way
The moving part is light,but with huge counter-force,the products affect lightly by heavy force. There is no special requirement for installation position.
6,Diversity Multy-purpose
Standard purpose includes:battery switch and backup equipment, DCvoltage power controlling and circuit safety protection device etc.,
7,Conforms with EU RoHS Instruction (2002/95/EC)
Product Series |
EVQ30 |
Appearance |
|
Types |
Types |
Contactor |
Type of main contactor system |
Bridge-form operation(SPST-NO-DM) |
Current type |
(DC) |
media type when cutting-off |
Inactive gas |
Operation method |
Power-driven |
rating operation system |
uninterrupted duty |
Rated value and limited value on main contactor |
Contactor polar |
With polar |
√ |
Without polar |
√ |
Rated operation voltage (Ue) |
12-900Vdc |
Rated operation current |
30A (2) |
Rating short-time tolerance current and duration time
|
90A 30sec. |
150A 10sec. |
Maximum cutiting-off voltage( one-time permitted) |
300A 350Vdc |
Connecting resistance on contactor(initial ) |
1mΩ Max.(at 1A) |
operating time(at 20ºC) |
25ms Max.(3) |
Bounce time(at 20ºC) |
7ms Max.(3) |
Release time(at 20ºC) |
12ms Max.(4) |
Operation life time |
Machinery life time |
1×106 (5) |
Electricity life time(2,4) |
With polar |
See graph-1 |
Without polar |
See graph-2 |
Dielectric function parameter |
insulation resistance |
Initial stage:100MΩ Min.(1) |
Life-time terminates:50MΩ Min.(1) |
rated impulse withstand voltage(initial) |
Main contact ininterface |
AC 2500 Vrms/1mA/1min.(latitude) |
Main contactor and coil interface |
AC 2500 Vrms/1mA/1min.(latitude) |
Machinery function |
Impulse |
20Gpeak value,11ms 1/2sinusoid(coil power setup) |
vibration |
20Gpeak value,80~2,000Hz,sinusoid |
Coil parameter |
Rated operation voltage scope |
12Vdc,24Vdc |
Coil polar |
× |
Power-saving circuit board |
× |
Assistant contactor(6) |
× |
Environmental parameter |
Use and storage the environmental temperature scope |
-40ºC~+85ºC |
Use and storage the environmental humidity scope |
5%~85% RH. |
weight |
120±5g |
safety rules and quality management system |
CE,CCC,UL |
1:measure the voltageDC500V,the testing position is as same as dielectric withstanding voltage
2:loading category:DC-1,L/R millisecond
3:enforce the rated operation voltage on coil, involves the contactor will bounce.
4:enforce the rated operation voltage on coil, without diode.
5:rated controlling capacity, transforming frequency, connceting and cutting-off ,ON : OFF=0.5second: 0.5second
6:assistant contactor parameter:2A@30VDC/3A@125VAC,600Vac 50/60Hz 1min.