Energy Storage Type Isolation Inverter for Powering Diagnostic Equipment in Hospital Diagnostic Trolleys

Product Details
Customization: Available
Nature of Source Flow: Passive inverter
Certification: ISO9001, CE
Manufacturer/Factory & Trading Company
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Fast Delivery
The supplier can deliver the goods within 15 days
Low MOQ
The MOQ for the supplier's products is 1
Customization from Samples
The supplier provides sample based customization services
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (22)
  • Energy Storage Type Isolation Inverter for Powering Diagnostic Equipment in Hospital Diagnostic Trolleys
  • Energy Storage Type Isolation Inverter for Powering Diagnostic Equipment in Hospital Diagnostic Trolleys
  • Energy Storage Type Isolation Inverter for Powering Diagnostic Equipment in Hospital Diagnostic Trolleys
  • Energy Storage Type Isolation Inverter for Powering Diagnostic Equipment in Hospital Diagnostic Trolleys
  • Energy Storage Type Isolation Inverter for Powering Diagnostic Equipment in Hospital Diagnostic Trolleys
  • Energy Storage Type Isolation Inverter for Powering Diagnostic Equipment in Hospital Diagnostic Trolleys
Find Similar Products
  • Overview
  • Company Profile
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Certifications
  • Installation Case
Overview

Basic Info.

Model NO.
BZP series
Output Power
40kw
Grid Type
off-Grid Inverter
Output Type
Multiple
Circuit Topologies
Full-Bridge Type
Nature of Wave String
Sine Wave Inverter
Type
DC/AC Inverters
Transport Package
Wooden Box
Specification
BZP-40kw
Trademark
Bangzhao or Sandi or OEM
Origin
China
HS Code
8504403090
Production Capacity
888sets/Year

Product Description

Energy storage type isolation inverter for powering diagnostic equipment in hospital diagnostic trolleys
Company Profile

         Bangzhao Electric Co.,Ltd is a company who was established in 2008 and specialized in developing and supplying of power products. The high performance of its products stems from the cutting-edge technology developed by the domestic top 100 engineers. During the past 10 years, we have been providing the best system solutions of Life PO4 battery pack cabinet,Boat inverter ,Car inverter,Solar inverter,Wind-Solar Hybrid inverter,lithium battery charger,PWM/MPPT solar charge controller,PV pump inverter,Explosion-proof inverter,DC combiner box,AC to DC battery cabinet ,Single Phase to 3 Phase Converter,Lithium battery storage system etc. to customers, it is widely applied in the industry of solar energy,wind power,water power,car,ship,train,hospital, aviation,automation,etc.
Energy Storage Type Isolation Inverter for Powering Diagnostic Equipment in Hospital Diagnostic Trolleys

Product Description

Multi-protection: This is isolation inverter also has many intelligent protection functions, such as battery over-voltage and low-voltage protection, high temperature protection, automatic overload protection, and short-circuit protection, etc., which ensures that your power supply is always stable and reliable in the complex and changing driving environment.
Multiple Battery Adaptation: This industrial frequency isolation inverter is suitable for a variety of vehicle batteries, such as lead-acid batteries, colloidal batteries, lithium batteries, etc., which can satisfy the power supply needs of different models and equipment.
Good compatibility: The output AC power is consistent with the utility waveform, which is compatible with all kinds of vehicle-mounted equipments without additional adaptation or modification. It can be equipped with the function of utility power complementary to ensure the uninterruptedness of power consumption.
Convenient maintenance: modularized structure makes after-sales maintenance more convenient and reduces maintenance cost and time.
Vibration-resistant design: Vehicle-mounted equipment is often exposed to bumps and vibrations, and this "industrial frequency isolation inverter" adopts a vibration-resistant design, which can ensure stable operation in the harsh driving environment.
Wide input range: Wide input voltage range adapts to DC inputs of different voltage levels to cope with voltage fluctuations in different regions and different vehicle models.
Compact and portable: small size, compact size, two people can easily carry it with bare hands, without professional tools or equipment. Easy to carry and install, suitable for small space environment.

 

Product Parameters
  1. Using the sixth generation efficient IPM intelligent module from Japanese Mitsubishi, high efficiency and stable performance. It with powerful protection function, the protection for short circuit, over load, over temperature is more safe and reliable. It's service life can up to 15 years or more.
  2. Intelligentized, modularized, simple structure design with powerful function.
  3. Two kinds of start mode: Step-down Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. This function is very convenient for users and also reduce frequency converter's usage, which reduced the cost of equipment investment, easy to connect wires and control.
  4. The output frequency can be setting via LCD panel, it's very convenient for customer.
  5. The output voltage can be set between -40 % to +20 % of rated voltage. And the output voltage is very accuracy ±1%.
  6. The DC input voltage range can be set. Over-voltage point, under-voltage point, over-voltage recovery point, under-voltage recovery point all can be setting via the LCD panel.
  7. Pure sine wave output. With good dynamic response less than 50MS, waveform distortion rate smaller, higher conversion efficiency and stable output voltage.
  8. Low Frequency Transformer, which ensures that inverter has high efficiency.
  9. High conversion efficiency, Max. Efficiency≥94%,if 48VDC input,the efficiency can more than 85%.
  10.  Adopts black pure aluminum radiator, which confirms the best radiating performance.
  11. Powerful data display function. LCD can display the DC input voltage, output frequency, phase voltage, phase current, AC bypass input voltage, output power KWH, time and date, temperature, fault code display.
  12. Wide input voltage can be set according to customer's requirement. Input voltage range can be selected from 150-400V or 300-600V or 400-800V.
  13. Wide input voltage can work without battery and solar charge controller,save more cost and With MPPT wide voltage input function, maximum use of solar power
  14. Optional function
  1. RS485 remote monitoring,
  2. AC bypass input,
  3. built in solar charge controller or AC to DC battery charger.
Energy Storage Type Isolation Inverter for Powering Diagnostic Equipment in Hospital Diagnostic TrolleysEnergy Storage Type Isolation Inverter for Powering Diagnostic Equipment in Hospital Diagnostic TrolleysEnergy Storage Type Isolation Inverter for Powering Diagnostic Equipment in Hospital Diagnostic TrolleysEnergy Storage Type Isolation Inverter for Powering Diagnostic Equipment in Hospital Diagnostic TrolleysEnergy storage type isolation inverter for powering diagnostic equipment in hospital diagnostic trolleys:

Model

BZP-40KW

Isolation mode

Low Frequency Transformer

PV Input

Voltage range (Vdc)

415-700Vdc

Rated current(A)

86A

AC Grid /Generator Input Rated voltage(Vac) 380V 3 Phase 

AC Output

Rated output power

40KW

Output waveform

Pure Sine Wave

Rated Voltage

380VAC±3%

Phases

3 phase 4 wires

Rated current(A)

60A per phase

Frequency

50Hz or 60Hz

Rated output voltage range (V)

220-480V 3 Phase voltage range optional

Power Factor(PF)

0.99

Overload Ability

150%, 5 seconds

Efficiency

>92%

Waveform distortion rate (THD)

<3%  linear load

Dynamic Response (0 to 100% load)

5%,≤50ms

Display

LCD

Running mode

Working continuously

Electrical insulation properties

2000Vac, 1 Minute

Protection Function

Protection

Input reverse polarity, under voltage, overvoltage, output over-current, short circuit, overheating etc.

Cooling method

Fan-cooled

Short-circuit protection

No automatic recovery, need to restart the machine

Working environment

Noise ( 1 meter)

≤50dB

Degree of protection

IP20(indoor)

Working Altitude(m)

≤2000

Working temperature

-25~+55ºC

relative humidity

0~90%,non-condensing

Energy Storage Type Isolation Inverter for Powering Diagnostic Equipment in Hospital Diagnostic TrolleysEnergy Storage Type Isolation Inverter for Powering Diagnostic Equipment in Hospital Diagnostic Trolleys
wide voltage pv input power inverter details:

 

Model

BZP-40KW

Isolation mode

Low Frequency Transformer

PV Input

Voltage range (Vdc)

250-600V or 400-800VDC optional

Rated current(A)

111A or 67A

AC Grid /Generator Input Rated voltage(Vac) 220V 1 Phase 

AC Output

Rated output power

40KW

Output waveform

Pure Sine Wave

Rated Voltage

220VAC±3%

Phases

1 phase 2 wires

Rated current(A)

181A 

Frequency

50Hz or 60Hz

Rated output voltage range (V)

220-480V 3 Phase voltage range optional

Power Factor(PF)

0.99

Overload Ability

150%, 5 seconds

Efficiency

>92%

Waveform distortion rate (THD)

<3%  linear load

Dynamic Response (0 to 100% load)

5%,≤50ms

Display

LCD

Running mode

Working continuously

Electrical insulation properties

2000Vac, 1 Minute

Protection Function

Protection

Input reverse polarity, under voltage, overvoltage, output over-current, short circuit, overheating etc.

Cooling method

Fan-cooled

Short-circuit protection

No automatic recovery, need to restart the machine

Working environment

Noise ( 1 meter)

≤50dB

Degree of protection

IP20(indoor)

Working Altitude(m)

≤2000

Working temperature

-25~+55ºC

relative humidity

0~90%,non-condensing

 

Above parameter only for reference ,could be custom made to user specifications.

Stand type low frequency power inverter:
Wiring place picture:
Energy Storage Type Isolation Inverter for Powering Diagnostic Equipment in Hospital Diagnostic Trolleys

RAL7035 color one:
Energy Storage Type Isolation Inverter for Powering Diagnostic Equipment in Hospital Diagnostic Trolleys

Detailed Photos
 

Energy Storage Type Isolation Inverter for Powering Diagnostic Equipment in Hospital Diagnostic Trolleys

Certifications
 

Energy Storage Type Isolation Inverter for Powering Diagnostic Equipment in Hospital Diagnostic Trolleys

Installation Case

Energy Storage Type Isolation Inverter for Powering Diagnostic Equipment in Hospital Diagnostic Trolleys

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier