Regulating Output Frequency of Inverter to Change The Speed of Motor

Application: High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Output Type: Triple
Principle of Work: V/F Control Transducer
Switch Mode: PWM Control
Main Circuit Type: Voltage
Voltage of Power Supply: High Voltage Variable-Frequency Drive
Customization:
Manufacturer/Factory & Trading Company
Diamond Member Since 2015

Suppliers with verified business licenses

Zhejiang, China
to see all verified strength labels (22)

Basic Info.

Model NO.
BZ300-T3 series
Link of Transformation
AC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Simple Type
Brand
Bangzhao or OEM
Display
Digital Display
Apply for
Motor,Pump and So on
Max Frequency
600Hz
Product Name
Frequency Inverter
Transport Package
Carton
Specification
CE
Trademark
BANGZHAO OR OEM
Origin
China
Production Capacity
9999PCS

Product Description


Regulating output frequency of inverter to change the speed of motor
 
BZ300 series inverter is a  versatile general-purpose inverters which was developed for  the
needs  of a  wide  range of  generic  customers through  a  market  research by  Yueqing Bangzhao electric Co.,  Ltd.The whole series  of BZ300 inverter has  independent ventilation,
which can   be   installed  outside   or   inside   the   radiator   cabinet;perfect   user  password
protection ,directly  input DC  bus terminal  and DC  powered fan  that enable the  non-standard products to be  compatible with the  DC bus running mode  that makes the  complex application debugging and operation was very easy, reliable, safe.

 
1.2.1Motor insulation inspection
The motor  insulation must be  inspected when motor for  the first time  used or unused  for a
long time, in case  the effectiveness of the winding insulationto damage  the inverter. Motor
attachment must separate from  inverter when insulated inspection, suggested the 500  V voltage
type megameter,   guarantee the insulation resistance not less than 5 M .
1.2.2Motor of the thermal protection
If choose motor  and converter does not  match the rated capacity,  especially the rated power
greater than motor inverter power rating, be sure to adjust the inverter motor protection in related
parameters value or in motor with thermal relay to before to motor protection.
1.2.3power frequency above operation
This inverter  can provide 0  Hz ~ 600  Hz output  frequency. If the  customer needs to  be in
frequency 50 Hz above operation, please consider the strength of the mechanical device.
1.2.4The vibration of mechanical device
Inverter  may  meet  load  machinery's
mechanical  resonance  point
in  some  output
frequency place,it can be set hopping frequency and parameters  within the inverter   to avoid.
1.2.5 Motor fever and noise
Because
the inverter's output voltage  is PWM waves, contain certain  harmonic , therefore,
the rise of temperature of the motor, noise and vibration frequency will run little increase.
1.2.6  When therer  are  pressure sensitive  devices  or capacitance  to  improve the  power
factor on the output side
Inverter is  PWM waves,  the output  side such  as the  capacitor with  improving electrical
power  factor  or  the  lightning  protection  with  pressure   sensitive  resistance,  it  easy  cause
instantaneous inverter over current even damage inverter, please do not use.
1.2.7The input and output terminal contactor of switching element etc

 
 
BZ300
User's manual
If contactor  is between  the power  and inverter  input side  , it  is not  allowed to  use this
contact device  control  inverter to  the rev.  Stop. It  need to  use this  contractor  to control  the
inverter rev. Stopping ,    interval an hour at least. Frequent charge-discharge is easily reduce the
inverter of the capacito the service lifer. If the output and motor with contact between the switch
device, shall  ensure  that no  output inverter  in the  hige  operation, or  it easily  cause inverter
module damaged.
1.2.8 Rated voltage value the use of outside
Not suitable for  user manual in  the provisions of the  voltage range allowed  outside use DR
series  inverter, it  easily cause  the  inverter device  damaged  . If  it  necessary, please  use  the
corresponding or step down device to deal with variable pressure
1.2.9 Change the three-phase input into the two phase input
Don't change  the three-phase inverter  into the  two phase in  DR series. Otherwise  it will
lead to malfunction or damage the inverter
1.2.10 Lightning shock protection
This series of inverter is equipped with a lightning over current protection device,
having
certain ability  of self-protection  for indirect  lightning.In the  frequent lightning place,   please
install the protective devices at the front end of the inverter.
1.2.11 The altitude and derating using
At an  altitude of  more than  1000m area, because  thin air  cause the  inverter cooling  effect
becoming poor,so it is necessary to derate use. Please consult our  company for technique in this
situation.
1.2.12 Some special usage
If the customer  was using when  required to book  recommendations provided by methods
other than when wiring diagram, such as dc bus, etc, please consult our company
1.2.13Converter scrap note
The main loop of the electrolytic capacitor and printed circuit boards electrolytic capacitors
on incineration  can explode.  Plastic incinerator  will produce  toxic gases.  Please as  industrial
waste processing.
1.2.14 Adapter motor
1)Standard adapter electric quadrupole squirrel-cage asynchronous induction motor. If the
motor please press the motor  rated current selection of inverter. If you  need to drive permanent
magnet synchronous motor of the occasion, please consult our company.
2)A variable frequency motor  cooling fan and rotor shaft is coaxially connected, speed is
reduced  when the  fan  cooling effect  is  reduced, therefore,  the  motor overheat  the  occasion
should be equipped with strong exhaust fan or replacement for variable frequency motor.
3)Converter  has a built-in adaptation  motor standard parameters, according to  the actual
situation it is necessary to motor parameter self  identification or modify the default values so as
to  accord  with the  actual  value,  otherwise  it  will  affect the  running  effect  and  protection
performance.
4)Because  the cable or motor internal  short circuit can cause inverter alarm,  even frying
machine. Therefore, please first for the initial installation of the motor and cable insulation short
test, routine maintenance is often  required for this test. Note, doing this  test must be tested part
of inverter and disconnect all.

 
 