"BZA" series intelligent high-frequency switch power supply modules are specially developed to meet the demands of modern DC system. The charger rectifiers are designed with world leading patent technology "resonant voltage type soft switching power supply technology". They feature high efficiency and stability, intelligent control, small size and light weight.
When short circuit, the output voltage drops to 0 immediately. Limit the short circuit current under 15% of rated output current. The module will not be damaged under short circuit state for a time, and resumes to work automatically after debugging.
110VDC rectifier for Substation--3 phases | |||
BZA110D10ZZ-3 | BZA110D20ZZ-3 | BZA110D40ZZ-3 | |
Input voltage | 380VAC(-15%~+15%) | ||
Output voltage | 88~150VDC | ||
Output current(A) | 1-10 | 2-20 | 4-40 |
Power(kW) | 1.5 | 3 | 6 |
Size (H × W × D) mm | 179×109×260 | 230×130×325 | 323×146×400 |
Weight(kg) | 4.7 | 7 | 14 |
Cooling method | Natural cooling | ||
Noise(dB) | 50 | ||
Efficiency | ≥94% | ||
Current stabilization | <±1% | ||
Voltage stabilization | <±0.5% | ||
Power factor | ≥0.94 | ||
Current imbalance in parallel operation | ≤ ± 3% | ||
Communication protocol | MODBUS with RS485 | ||
Operation ambient temperature | -10°C ~ 40ºC | ||
Storage temperature | -40°C~ 60ºC | ||
Time delay of start-up | 3~8s | ||
Ripple factor | ≤0.2% | ||
Automatic current limiting | When output is over the limit value, the output current will not increase and keep constant current output. | ||
Output overvoltage protection function | When output overvoltage occurs(160±3VDC), the module locks up automatically. | ||
Output short circuit protection | When output short circuit, the module draws the output voltage to 0VDC immediately. The module will resume when the short circuit disappear. |
||
Insulating strength | lnput to housing (earth) 2100VAC 1minute 5mA, no breakdown, no flashover Input to output 2100VAC 1minute 4mA, no breakdown, no flashover Output to housing (earth) 2100VAC 1minute 4mA, no breakdown, no fla |